Analisis Kualitas Mikrobiologi Air Minum Isi Ulang di Depo Air Minum Isi Ulang Kelurahan Jemur Wonosari Kota Surabaya

  • Ajeng Dwi Rahmawati Universitas Nahdlatul Ulama Surabaya
  • Akas Yekti Pulih Asih Universitas Nahdlatul Ulama Surabaya
  • Edza Aria Wikurendra Szent István University Kaposvár Campus
Keywords: Drinking Water, Microbiological Analysis, Refill Drinking Water Depot

Abstract

Background:

Based on the preliminary test using laboratory tests from three refill drinking water samples in Jemur Wonosari Village, all three were positive for Coliform. Therefore, researchers are interested in researching Analysis of the Microbiological Quality of Refilled Drinking Water at the Refill Drinking Water Depot in Jemur Wonosari Village.

Objectives:

Knowing the microbiological quality of refill drinking water produced at the refill drinking water depot in Jemur Wonosari Village.

Research Methods:

This research is a descriptive study with a cross-sectional quantitative approach using primary and secondary data sources. The population in this study were all 13 refill drinking water depots. The research takes the total population. Refillable drinking water samples were tested at the Gayung Sari Regional Health Service Laboratory. Data analysis used descriptive analysis by comparing the results of laboratory tests with Permenkes 492 of 2010.

Results:

The results showed that 13 samples found that 13 samples were positive for Coliform, and 13 samples were negative for Escherichia coli. According to Permenkes No. 429 of 2010, the maximum limit per 100 ml of sample is 0. So the 13 samples of refill drinking water based on microbiological parameters, namely Escherichia coli in refilled drinking water, meet the standard while the Coliform does not meet the standard.

Conclusion:

All refill drinking water depots in Keluraham Jemur Wonosari produce refilled drinking water whose quality does not meet the government's microbiological standards. There is a need for increased supervision and guidance at refill drinking water depots.

 

Keywords: Drinking Water, Microbiological Analysis, Refill Drinking Water Depot

Downloads

Download data is not yet available.

References

Apriliana, E., Ramadhian, M., & Gapila, M. (2014). Bacteriological quality of refill drinking water at refill drinking water depots in Bandar Lampung. Juke.
Copeland, C. C., Beers, B. B., Thompson, M. R., Fitzgerald, R. P., Barrett, L. J., Sevilleja, J. E., Alencar, S., Lima, A. A. M., & Guerrant, R. L. (2009). Faecal contamination of drinking water in a Brazilian shanty town: Importance of household storage and new human faecal marker testing. Journal of Water and Health. https://doi.org/10.2166/wh.2009.081
Dewanti, R. I. A. A. Y. U. (2017). Analisis Kualitas Bakteriologis Air Minum, Personal Hygiene Dan Kejadian Diare Pada Konsumen Di Kelurahan Sememi, Kecamatan Benowo. Universitas Airlangga.
Dinas Kesehatan Kota Surabaya. (2018). Profil Dinas Kesehatan Kota Surabaya. Dinas Kesehatan.
Indonesia, B.-S. (2019). Statistik Indonesia 2019. In Statistical Year Book of Indonesia 2019.
Kepmenkes RI. (2002). Syarat-Syarat dan Pengawasan Kualitas Air Minum. Kemenkes RI.
Marpaung, M. D. O., & Marsono, B. D. (2013). Uji Kualitas Air Minum Isi Ulang di Kecamatan Sukolilo Surabaya Ditinjau dari Perilaku dan Pemeliharaan Alat. JURNAL TEKNIK POMITS Vol. 2, No. 2, (2013) ISSN: 2337-3539 (2301-9271 Print).
Meylani, V., & Putra, R. R. (2019). Analisis E. Coli Pada Air Minum Dalam Kemasan Yang Beredar Di Kota Tasikmalaya. Bioeksperimen: Jurnal Penelitian Biologi. https://doi.org/10.23917/bioeksperimen.v5i2.9241
Permenkes. (2010). Peraturan Menteri Kesehatan Republik Indonesia Nomor 492/Menkes/Per/IV/2010 Tentang Persyaratan Kualitas Air Minum. In Peraturan Menteri Kesehatan Republik Indonesia.
Waliulu, K. T. (2018). Analisis Mikroorganisme Air Minum Isi Ulang Pada Dispenser Di RSUD Dr. M. Haulussy Kota Ambon. Jurnal Nasional Ilmu Kesehatan.
Wandrivel, R., Suharti, N., & Lestari, Y. (2012). Kualitas Air Minum Yang Diproduksi Depot Air Minum Isi Ulang Di Kecamatan Bungus Padang Berdasarkan Persyaratan Mikrobiologi. Jurnal Kesehatan Andalas. https://doi.org/10.25077/jka.v1i3.84
Published
2021-06-30
How to Cite
Dwi Rahmawati, A., Pulih Asih, A. Y., & Wikurendra, E. A. (2021). Analisis Kualitas Mikrobiologi Air Minum Isi Ulang di Depo Air Minum Isi Ulang Kelurahan Jemur Wonosari Kota Surabaya. KESMAS UWIGAMA: Jurnal Kesehatan Masyarakat, 7(1), 159-166. https://doi.org/10.24903/kujkm.v7i1.1181
Section
Articles